Model NO.: abc cable
-
Conductor Type: Stranded
-
Conductor Material: Aluminum
-
Insulation Material: XLPE
-
Range of Application: Overhead
-
Brand: Huatong
-
Color: as Per Your Customers ′ Request
-
Trademark: Huatong
-
Origin: China
-
Type: Insulated
-
Application: Overhead, Underground
-
Sheath Material: No
-
Material Shape: Round Wire
-
Certification: ISO9001, CE, CCC, RoHS
-
Voltage: LV. Mv. Hv
-
Insulated Materials: PVC/PE/XLPE
-
Transport Package: All Wooden, Steel Wooden or Steel Package
-
HS Code: 8544492100
 Low Voltage Type and none Jacket ABC cable with bare messenger IEC standardApplications:
To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene Insulation or 90°C maximum for crosslinked insulation.
Construction:
Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR or 6201 alloy neutral messenger.
Standards:
B-230 Aluminum Wire 1350-H19 for Electrical Purposes
B-231 Aluminum Conductors, Concentric-Lay-Stranded
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.
There is a lot of debate still going on as to whether copper is better for electrical purposes or aluminum. If price was not a critical factor, most would suggest going in for silver as it is said to be the best conductor of electricity but has a low strength. However, when it comes to electrical wiring, price is a factor, as is efficiency.
Triplex Aluminum Service Drop Cable
Code Word |
Phase conductor |
Bare Neutral Messenger |
Weight Per 1000 ft. (lbs.) |
Allowable Ampacity+ |
Size (AWG) |
Stranding |
Insul. Thick. (mils) |
Size (AWG) |
Size (kcmil) |
Strand- ing |
Rated Strength (lbs.) |
XLP |
POLY |
XLP |
POLY |
AAAC 6201 ALLOY FULL NEUTRAL MESSENGER |
Minex |
6 |
1 |
45 |
6 |
30.58 |
7 |
1110 |
101 |
101 |
85 |
70 |
Hippa |
6 |
7 |
45 |
6 |
30.58 |
7 |
1110 |
107 |
107 |
85 |
70 |
Prawn |
4 |
1 |
45 |
4 |
48.69 |
7 |
1760 |
152 |
152 |
115 |
90 |
Barnacle |
4 |
7 |
45 |
4 |
48.69 |
7 |
1760 |
160 |
160 |
115 |
90 |
Shrimp |
2 |
7 |
45 |
2 |
77.47 |
7 |
2800 |
243 |
243 |
150 |
120 |
Gammarus |
1/0 |
7 |
60 |
1/0 |
123.3 |
7 |
4460 |
390 |
390 |
205 |
160 |
Leda |
1/0 |
9 |
60 |
1/0 |
123.3 |
7 |
4460 |
384 |
384 |
205 |
160 |
Dunganese |
2/0 |
7 |
60 |
2/0 |
155.4 |
7 |
5390 |
474 |
474 |
235 |
185 |
Cyclops |
2/0 |
11 |
60 |
2/0 |
155.4 |
7 |
5390 |
474 |
474 |
235 |
185 |
Flustra |
3/0 |
17 |
60 |
3/0 |
195.7 |
7 |
6790 |
587 |
587 |
275 |
215 |
Lepas |
4/0 |
18 |
60 |
4/0 |
246.9 |
7 |
8560 |
728 |
728 |
315 |
245 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. |
Â
Code Word |
Phase conductor |
Bare Neutral Messenger |
Weight Per 1000 ft. (lbs.) |
Allowable Ampacity+ |
Size (AWG) |
Stranding |
Insul. Thick. (mils) |
Size (AWG) |
Size (kcmil) |
Strand- ing |
Rated Strength (lbs.) |
XLP |
POLY |
XLP |
POLY |
AAAC 6201 ALLOY REDUCED NEUTRAL MESSANGER |
Artemia |
4 |
1 |
45 |
6 |
30.58 |
7 |
1110 |
135 |
135 |
115 |
90 |
Crab |
4 |
7 |
45 |
6 |
30.58 |
7 |
1110 |
143 |
143 |
115 |
90 |
Solaster |
2 |
7 |
45 |
4 |
48.69 |
7 |
1760 |
216 |
216 |
150 |
120 |
Sandcrab |
1/0 |
7 |
60 |
2 |
77.47 |
7 |
2800 |
347 |
347 |
205 |
160 |
Echinus |
1/0 |
9 |
60 |
2 |
77.47 |
7 |
2800 |
341 |
341 |
205 |
160 |
Crayfish |
2/0 |
7/w |
60 mls |
2/0 |
-- |
7 |
2510 |
485.8 |
455.3 |
235 Amps |
185 Amps |
Sipho |
2/0 |
7/w |
60 mls |
2/0 |
-- |
7 |
2510 |
485.8 |
455.3 |
235 Amps |
185 Amps |
Fulgar |
3/0 |
17 |
60 |
1/0 |
123.3 |
7 |
4460 |
519 |
519 |
275 |
215 |
Arca |
4/0 |
18 |
60 |
2/0 |
155.4 |
7 |
5390 |
643 |
643 |
315 |
245 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201. |
Â
Â
Code Word |
Phase conductor |
Bare Neutral Messenger |
Weight Per 1000 ft. (lbs.) |
Allowable Ampacity+............... |
Size (AWG) |
Stranding |
Insul. Thick. (mils) |
Size (AWG) |
Strand- ing |
Rated Strength (lbs.) |
XLP |
POLY |
XLP |
POLY |
AAC NEUTRAL-MESSENGER |
Haiotis |
6 |
7/w |
45 mls |
6 |
7 |
563 |
109.1 |
101.6 |
85 Amps |
70 Amps |
Patella |
6 |
7 |
45 |
6 |
7 |
563 |
103 |
103 |
85 |
70 |
Fusus |
4 |
7/w |
45 mls |
4 |
7 |
881 |
161.8 |
151.7 |
115 Amps |
90 Amps |
Oyster |
4 |
7 |
45 |
4 |
7 |
881 |
154 |
154 |
115 |
90 |
Clam |
2 |
7 |
45 |
2 |
7 |
1350 |
233 |
233 |
150 |
120 |
Murex |
1/0 |
7 |
60 |
1/0 |
7 |
1990 |
374 |
374 |
205 |
160 |
Purpura |
1/0 |
9 |
60 |
1/0 |
7 |
1990 |
368 |
368 |
205 |
160 |
Nassa |
2/0 |
7 |
60 |
2/0 |
7 |
2510 |
462 |
462 |
235 |
185 |
Melita |
3/0 |
17 |
60 |
3/0 |
19 |
3310 |
562 |
562 |
275 |
215 |
Portunus |
4/0 |
18 |
60 |
4/0 |
19 |
4020 |
696 |
696 |
315 |
245 |
Nannynose |
336.4 |
19 |
80 |
336.4 |
19 |
6146 |
1118 |
1118 |
420 |
325 |
* Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun. |
Â
Code Word |
Phase conductor |
Bare Neutral Messenger |
Weight Per 1000 ft. (lbs.) |
Allowable Ampacity+ |
Size (AWG) |
Stranding |
Insul. Thick. (mils) |
Size (AWG) |
Strand- ing |
Rated Strength (lbs.) |
XLP |
POLY |
XLP |
POLY |
ASCR NEUTRAL-MESSENGER |
Paludina |
6 |
1 |
45 |
6 |
6/1 |
1190 |
109 |
109 |
85 |
70 |
Voluta |
6 |
7 |
45 |
6 |
6/1 |
1190 |
114 |
114 |
86 |
70 |
Whelk |
4 |
1 |
45 |
4 |
6/1 |
1860 |
-- |
164 |
115 |
90 |
Periwinkle |
4 |
7 |
45 |
4 |
6/1 |
1860 |
172 |
172 |
115 |
90 |
Conch |
2 |
7 |
60 |
1/0 |
6/1 |
4380 |
420 |
420 |
205 |
160 |
Neritina |
1/0 |
7 |
60 |
1/0 |
6/1 |
4380 |
420 |
420 |
205 |
160 |
Cenia |
1/0 |
9 |
60 |
1/0 |
6/1 |
4380 |
414 |
414 |
205 |
160 |
Runcina |
2/0 |
7 |
60 |
2/0 |
6/1 |
5310 |
520 |
520 |
235 |
185 |
Triton |
2/0 |
11 |
60 |
2/0 |
6/1 |
5310 |
512 |
512 |
235 |
185 |
Mursia |
3/0 |
17 |
60 |
3/0 |
6/1 |
6620 |
635 |
635 |
275 |
215 |
Zuzara |
4/0 |
18 |
60 |
4/0 |
6/1 |
8350 |
789 |
789 |
315 |
245 |
Limpet |
336.4 |
19 |
80 |
336.4 |
18/1 |
8680 |
1167 |
1167 |
420 |
325 |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun. |
Â
Code Word |
Phase conductor |
Bare Neutral Messenger |
Weight Per 1000 ft. (lbs.) |
Allowable Ampacity+ |
Size (AWG) |
Stranding |
Insul. Thick. (mils) |
Size (AWG) |
Strand- ing |
Rated Strength (lbs.) |
XLP |
POLY |
XLP |
POLY |
ASCR REDUCED NEUTRAL-MESSENGER |
Scallop |
4 |
1 |
45 |
6 |
6/1 |
1190 |
-- |
142 |
115 |
90 |
Strombus |
4 |
7 |
45 |
6 |
6/1 |
1190 |
151 |
151 |
115 |
90 |
Cockle |
2 |
7 |
45 |
4 |
6/1 |
1190 |
220 |
220 |
150 |
120 |
Janthina |
1/0 |
7 |
60 |
2 |
6/1 |
2853 |
366 |
366 |
205 |
160 |
Ranella |
1/0 |
9 |
60 |
2 |
6/1 |
2853 |
360 |
360 |
205 |
160 |
Cavolinia |
2/0 |
7 |
60 |
1 |
6/1 |
3550 |
453 |
453 |
235 |
185 |
Clio |
2/0 |
11 |
60 |
1 |
6/1 |
3550 |
444 |
444 |
235 |
185 |
Sanddollar |
3/0 |
19/w |
60 mls |
1/0 |
6/1 |
4380 |
565 |
552 |
275 Amps |
215 Amps |
Aega |
3/0 |
17 |
60 |
1/0 |
6/1 |
4380 |
549 |
549 |
275 |
215 |
Cuttlefish |
4/0 |
19/w |
60 mls |
2/0 |
6/1 |
5310 |
699 |
684 |
315 Amps |
245 Amps |
Cerapus |
4/0 |
18 |
60 |
2/0 |
6/1 |
5310 |
681 |
681 |
315 |
245 |
Cowery |
336.4 |
19 |
80 mls |
336/4 |
18/1 |
8680 |
1209 |
1167 |
420 Amps |
325 Amps |
*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun. |
Comapny product :Product line :Customer Feedback :
Basic LED Flood Light
Waterproof Flood Light,Flood Light LED,200W LED Flood Light
Chandelier & Pendant Light,Basic LED Tube Light Co., Ltd. , http://www.chledtube.com