Media Voltage XLPE Insulated power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable.
Prpperty:
1.The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2.In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3.The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4.Excellent electrical performance, resistance to chemical corrosion.
5.They can stand advisable traction when laid.They can stand traction from Outside.Left low smoke halogen-free after burned.Retard the burning of the cable.
Specification:
Standard:
IEC60502,designing and manufacturing special power cable according to the other standards required by the customers.
1)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper TapeNormal Thickness of Outer Sheath
Approx.
Overall Dia.Approx. Net Weight
Max. D.C. Resistance of Conductor at 20C
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
kg/km
kg/km
25
6.0
2.5
0.12
1.5
17.6
0.34
0.49
1.2000
0.7270
35
7.0
2.5
0.12
1.5
18.5
0.39
0.60
0.8680
0.5240
50
8.3
2.5
0.12
1.6
20.0
0.46
0.74
0.6410
0.3870
70
9.7
2.5
0.12
1.6
21.5
0.55
0.96
0.4430
0.2680
95
11.3
2.5
0.12
1.7
23.3
0.66
1.23
0.3200
0.1930
120
13
2.5
0.12
1.7
24.8
0.77
1.48
0.2530
0.1530
150
14.6
2.5
0.12
1.8
26.4
0.87
1.77
0.2060
0.1240
185
15.9
2.5
0.12
1.8
28.1
1.01
2.13
0.1640
0.0991
240
18.3
2.6
0.12
1.9
30.9
1.23
2.71
0.1250
0.0754
300
20.4
2.8
0.12
2.0
33.6
1.48
3.32
0.1000
0.0601
400
23.2
3.0
0.12
2.1
37.0
1.81
4.16
0.0778
0.0470
500
26.4
3.2
0.12
2.2
41.1
2.24
5.27
0.0605
0.0366
630
30.1
3.2
0.12
2.3
45.0
2.73
6.62
0.0469
0.0283
Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper TapeNormal Thickness of Outer Sheath
Approx.
Overall Dia.Approx. Net Weight
Max. D.C. Resistance of Conductor at 20C
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
kg/km
kg/km
25
6.0
3.4
0.12
1.5
19.4
0.40
0.55
1.2000
0.7270
35
6.9
3.4
0.12
1.6
20.5
0.45
0.66
0.8680
0.5240
50
8.2
3.4
0.12
1.6
21.8
0.52
0.80
0.6410
0.3870
70
9.7
3.4
0.12
1.7
23.5
0.62
1.03
0.4430
0.2680
95
11.3
3.4
0.12
1.7
25.1
0.73
1.30
0.3200
0.1930
120
12.8
3.4
0.12
1.8
26.8
0.85
1.56
0.2530
0.1530
150
14.2
3.4
0.12
1.8
28.2
0.95
1.85
0.2060
0.1240
185
15.9
3.4
0.12
1.9
30.1
1.10
2.22
0.1640
0.0991
240
18.3
3.4
0.12
2.0
32.7
1.33
2.80
0.1250
0.0754
300
20.4
3.4
0.12
2.0
34.8
1.54
3.39
0.1000
0.0601
400
23.2
3.4
0.12
2.2
38.0
1.87
4.22
0.0778
0.0470
500
26.4
3.4
0.12
2.2
41.5
2.26
5.29
0.0605
0.0366
630
30.1
3.4
0.12
2.4
45.6
2.78
6.67
0.0469
0.0283
3)8.7/10(15)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper TapeNormal Thickness of Outer Sheath
Approx.
Overall Dia.Approx. Net Weight
Max. D.C. Resistance of Conductor at 20C
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
kg/km
kg/km
25
6.0
4.5
0.12
1.6
21.8
0.48
0.63
1.2000
0.7270
35
6.9
4.5
0.12
1.7
22.9
0.54
0.75
0.8680
0.5240
50
8.2
4.5
0.12
1.7
24.2
0.61
0.89
0.6410
0.3870
70
9.7
4.5
0.12
1.8
25.9
0.72
1.13
0.4430
0.2680
95
11.3
4.5
0.12
1.8
27.5
0.84
1.40
0.3200
0.1930
120
12.8
4.5
0.12
1.9
29.2
0.96
1.67
0.2530
0.1530
150
14.2
4.5
0.12
1.9
30.6
1.06
1.96
0.2060
0.1240
185
15.9
4.5
0.12
2.0
32.5
1.22
2.34
0.1640
0.0991
240
18.3
4.5
0.12
2.1
35.1
1.46
2.93
0.1250
0.0754
300
20.4
4.5
0.12
2.1
37.2
1.68
3.52
0.1000
0.0601
400
23.2
4.5
0.12
2.2
40.2
2.00
4.35
0.0778
0.0470
500
26.4
4.5
0.12
2.3
43.9
2.43
5.45
0.0605
0.0366
630
30.1
4.5
0.12
2.4
47.8
2.93
6.83
0.0469
0.0283
4)12/20(24)kV, 12.7/22(24)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper TapeNormal Thickness of Outer Sheath
Approx.
Overall Dia.Approx. Net Weight
Max. D.C. Resistance of Conductor at 20C
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
kg/km
kg/km
25
Â
Â
Â
Â
Â
Â
Â
Â
Â
35
6.9
5.5
0.12
1.7
24.9
0.62
0.83
0.8680
0.5240
50
8.2
5.5
0.12
1.8
26.4
0.70
0.98
0.6410
0.3870
70
9.7
5.5
0.12
1.8
27.9
0.80
1.21
0.4430
0.2680
95
11.3
5.5
0.12
1.9
29.7
0.94
1.50
0.3200
0.1930
120
12.8
5.5
0.12
1.9
31.2
1.05
1.77
0.2530
0.1530
150
14.2
5.5
0.12
2.0
32.8
1.17
2.07
0.2060
0.1240
185
15.9
5.5
0.12
2.0
34.5
1.33
2.45
0.1640
0.0991
240
18.3
5.5
0.12
2.1
37.1
1.57
3.04
0.1250
0.0754
300
20.4
5.5
0.12
2.2
39.4
1.81
3.66
0.1000
0.0601
400
23.2
5.5
0.12
2.3
42.4
2.14
4.49
0.0778
0.0470
500
26.4
5.5
0.12
2.4
46.1
2.58
5.61
0.0605
0.0366
630
30.1
5.5
0.12
2.4
49.8
3.10
6.99
0.0469
0.0283
5)18/30(36)kV,19/33(36)kV,Single Core,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper TapeNormal Thickness of Outer Sheath
Approx.
Overall Dia.Approx. Net Weight
Max. D.C. Resistance of Conductor at 20C
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
kg/km
kg/km
25
Â
Â
Â
Â
Â
Â
Â
Â
Â
35
Â
Â
Â
Â
Â
Â
Â
Â
Â
50
8.2
8.0
0.12
2.0
31.8
0.95
1.23
0.6410
0.3870
70
9.7
8.0
0.12
2.0
33.3
1.07
1.47
0.4430
0.2680
95
11.3
8.0
0.12
2.1
35.1
1.21
1.78
0.3200
0.1930
120
12.8
8.0
0.12
2.1
36.6
1.34
2.05
0.2530
0.1530
150
14.2
8.0
0.12
2.2
38.2
1.47
2.37
0.2060
0.1240
185
15.9
8.0
0.12
2.2
39.9
1.64
2.76
0.1640
0.0991
240
18.3
8.0
0.12
2.3
42.5
1.90
3.37
0.1250
0.0754
300
20.4
8.0
0.12
2.4
44.8
2.16
4.01
0.1000
0.0601
400
23.2
8.0
0.12
2.4
47.6
2.52
4.87
0.0778
0.0470
500
26.4
8.0
0.12
2.5
51.3
2.98
6.01
0.0605
0.0366
630
30.1
8.0
0.12
2.6
55.2
3.54
7.43
0.0469
0.0283
6)3.6/6(7.2)kV,3.6/6.6(7.2)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper TapeNormal Thickness of Outer Sheath
Approx.
Overall Dia.Approx. Net Weight
Max. D.C. Resistance of Conductor at 20C
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
kg/km
kg/km
25
6.0
2.5
0.1
2.0
34.6
1.13
1.58
1.2000
0.7270
35
6.9
2.5
0.1
2.1
36.8
1.29
1.92
0.8680
0.5240
50
8.2
2.5
0.1
2.2
39.8
1.51
2.36
0.6410
0.3870
70
9.7
2.5
0.1
2.3
43.2
1.81
3.04
0.4430
0.2680
95
11.3
2.5
0.1
2.4
46.9
2.17
3.87
0.3200
0.1930
120
12.8
2.5
0.1
2.4
50.1
2.53
4.69
0.2530
0.1530
150
14.2
2.5
0.1
2.5
53.3
2.90
5.60
0.2060
0.1240
185
15.9
2.5
0.1
2.6
57.2
3.40
6.77
0.1640
0.0991
240
18.3
2.6
0.1
2.8
63.2
4.12
8.55
0.1250
0.0754
300
20.4
2.8
0.1
3.0
69.0
4.89
10.46
0.1000
0.0601
400
23.2
3.0
0.1
3.4
76.7
6.10
13.18
0.0778
0.0470
500
26.4
3.2
0.1
3.6
85.7
8.10
16.55
0.0605
0.0366
7)6/10(12)kV,6.35/11(12)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper TapeNormal Thickness of Outer Sheath
Approx.
Overall Dia.Approx. Net Weight
Max. D.C. Resistance of Conductor at 20C
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
kg/km
kg/km
25
6.0
3.4
0.1
2.1
38.7
1.30
1.75
1.2000
0.7270
35
6.9
3.4
0.1
2.2
40.9
1.47
2.22
0.8680
0.5240
50
8.2
3.4
0.1
2.3
43.9
1.70
2.50
0.6410
0.3870
70
9.7
3.4
0.1
2.4
47.3
2.02
3.25
0.4430
0.2680
95
11.3
3.4
0.1
2.5
51.0
2.42
4.12
0.3200
0.1930
120
12.8
3.4
0.1
2.6
54.4
2.79
4.95
0.2530
0.1530
150
14.2
3.4
0.1
2.7
57.6
3.17
5.87
0.2060
0.1240
185
15.9
3.4
0.1
2.8
61.5
3.69
7.06
0.1640
0.0991
240
18.3
3.4
0.1
2.9
66.9
4.38
8.82
0.1250
0.0754
300
20.4
3.4
0.1
3.1
71.8
5.11
10.68
0.1000
0.0601
400
23.2
3.4
0.1
3.3
78.3
6.24
13.32
0.0778
0.0470
500
26.4
3.4
0.1
3.5
86.4
7.63
16.50
0.0605
0.0366
8)8.7/10(15)kV,Three Cores,Al or Cu/XLPE/CTS/PVC Unarmoured Power Cable
Normal Cross Section of Conductor
Normal Diameter of Conductor
Normal Thickness of Insulation
Normal Thickness of
Copper TapeNormal Thickness of Outer Sheath
Approx.
Overall Dia.Approx. Net Weight
Max. D.C. Resistance of Conductor at 20C
Al Conductor
Cu Conductor
Al Conductor
Cu Conductor
mm2
mm
mm
mm
mm
mm
kg/m
kg/m
kg/km
kg/km
25
6.0
4.5
0.1
2.3
43.9
1.57
2.02
0.9270
0.7270
35
6.9
4.5
0.1
2.4
46.0
3kw Light Guide Column Section
12kv XLPE Insulation Copper or Aluminium Swa Power Cable
Model NO.: 12kv SWA
Wire Core Material: Copper or Aluminium
Certification: ISO, CCC, SABS
Brand: Jiapu
Trademark: JP
Transport Package: Export Wooden Drum or Wooden-Steel Drum
Specification: 3*50mm2/3*70mm2
Origin: China
HS Code: 8544601200
Model NO.: 12kv SWA
Wire Core Material: Copper or Aluminium
Certification: ISO, CCC, SABS
Brand: Jiapu
Trademark: JP
Transport Package: Export Wooden Drum or Wooden-Steel Drum
Specification: 3*50mm2/3*70mm2
Origin: China
HS Code: 8544601200
Application: