1. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 70° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed:
Nominal cross section of conductor ≤ 300mm2: 160° C;
Nominal cross section of conductor >300mm2: 140° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For multi-core cable: Not less than 15 times of the diameter of cable
2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or in conduit, unable to bear external mechanical force.
3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.
pvc insulated steel wire armoured construction power cable size Â
Â
Â
1) Standard :IEC60502,GB/T 12706
Â
2).Voltage :0.6/1KV
Â
3).Specification:
Â
Type | Designation | Application |
VV | Copper conductor ,PVC insulated ,PVC sheathed power cable | For laying indoors, in tunnel or cable trench,unable to bear extermal mechanical forces. Single core cable is not permissible to lay in magnetic duct |
VLV | Aluminium conductor ,PVC insulated ,PVC sheathed power cable | |
VY | Copper conductor, PVC insulated, PE sheathed power cable | |
VLY | Aluminium conductor ,PVC insulated ,PE sheathed power cable | |
VV22 | Copper conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable | For laying indoors, in cable trench or direct in ground ,able to bear external mechanical forces, but unable to bear pulling force |
VLV22 | Aluminium conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable | |
VV23 | Copper conductor ,PVC insualted ,steel tape armoured ,PE sheathed power cable | |
VLV23 | Alunminium conductor ,PVC insulated ,steel tape armoured ,PE sheathed power cable | |
VV32 | Copper conductor, PVC insulated, steel wire armoured,PVC insulated power cable  |
For laying indoors, in cable or direct in ground ,able to bear external mechanical forces, but unable to bear large pulling forces |
VLV32 | Aluminium conductor, PVC insulated ,steel tape armoured ,PVC sheathed power cable | |
VV33 | Copper conductor, PVC insulated steel wire armoured , PE sheathed power cable | |
VLV33 | Aluminium conductor , PVC insulated , streel wire armoured ,PE sheathed power cable | |
Note: The armoured single core cables is only used for D.C.system. As for A.C.system,non-magnetic armored material should be applied |
4).nominal cross-sectional areas:1.5 mm2Â , 2.5 mm2Â Â ,4 mm2Â , 6 mm2Â , 10 mm2Â Â , 16 mm2Â ,25 mm2Â Â , 35 mm2Â , 50 mm2Â Â ,70 mm2Â Â , 95 mm2Â Â ,120 mm2Â Â ,150 mm2Â ,185 mm2Â Â ,240 mm2Â ,300 mm2Â 400 mm2Â 500 mm2Â 630 mm2Â 800 mm2
Â
5)production range: single core cable from 1.5 mm2Â Â to 800 mm2,muli-core cable from 1.5 mm2Â Â to 400 mm2
Â
6).operating characteristics:
Rated power-frequency voltage u0/u:0.6/1 KV
Max permissible continuous operating temperature of conductor 70
Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): cross-section of conductor 300 mm2
 Â
The bending radius of single core cable should not be less than 20 times of the cable diameter ,the bending radius of multi-core cable should not be less than 15 times of the cable diameter
 Copper XLPE Insulated PVC Sheath  Aluminum Steel Wire Armoured Underground Power CableÂ
1. Operating Characteristics
Rated voltage: 0.6/1(1.2)kV
Max. Permissible continuous operating temperature of conductor: 70° C
Max. Temperature of conductor during short-circuit (5s max. Duration) shall not exceed:
Nominal cross section of conductor ≤ 300mm2: 160° C;
Nominal cross section of conductor >300mm2: 140° C
The ambient temperature under installation should not be lower than: 0 ° C
The bending radius of cable is recommended as following:
For single core cable: Not less than 20 times of the diameter of cable
For multi-core cable: Not less than 15 times of the diameter of cable
2. Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, in tunnel, in cable trench or in conduit, unable to bear external mechanical force.
3. Manufacturing Standards
IEC 60502-1 & Chinese national standard GB/T 12706-2008 We can produce above cables according to popular international standards such as ASTM, BS, DIN, NF &AS/NZ also.
pvc insulated steel wire armoured construction power cable size Â
Â
Â
1) Standard :IEC60502,GB/T 12706
Â
2).Voltage :0.6/1KV
Â
3).Specification:
Â
Type | Designation | Application |
VV | Copper conductor ,PVC insulated ,PVC sheathed power cable | For laying indoors, in tunnel or cable trench,unable to bear extermal mechanical forces. Single core cable is not permissible to lay in magnetic duct |
VLV | Aluminium conductor ,PVC insulated ,PVC sheathed power cable | |
VY | Copper conductor, PVC insulated, PE sheathed power cable | |
VLY | Aluminium conductor ,PVC insulated ,PE sheathed power cable | |
VV22 | Copper conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable | For laying indoors, in cable trench or direct in ground ,able to bear external mechanical forces, but unable to bear pulling force |
VLV22 | Aluminium conductor ,PVC insulated ,steel tape armoured ,PVC sheathed power cable | |
VV23 | Copper conductor ,PVC insualted ,steel tape armoured ,PE sheathed power cable | |
VLV23 | Alunminium conductor ,PVC insulated ,steel tape armoured ,PE sheathed power cable | |
VV32 | Copper conductor, PVC insulated, steel wire armoured,PVC insulated power cable  |
For laying indoors, in cable or direct in ground ,able to bear external mechanical forces, but unable to bear large pulling forces |
VLV32 | Aluminium conductor, PVC insulated ,steel tape armoured ,PVC sheathed power cable | |
VV33 | Copper conductor, PVC insulated steel wire armoured , PE sheathed power cable | |
VLV33 | Aluminium conductor , PVC insulated , streel wire armoured ,PE sheathed power cable | |
Note: The armoured single core cables is only used for D.C.system. As for A.C.system,non-magnetic armored material should be applied |
4).nominal cross-sectional areas:1.5 mm2Â , 2.5 mm2Â Â ,4 mm2Â , 6 mm2Â , 10 mm2Â Â , 16 mm2Â ,25 mm2Â Â , 35 mm2Â , 50 mm2Â Â ,70 mm2Â Â , 95 mm2Â Â ,120 mm2Â Â ,150 mm2Â ,185 mm2Â Â ,240 mm2Â ,300 mm2Â 400 mm2Â 500 mm2Â 630 mm2Â 800 mm2
Â
5)production range: single core cable from 1.5 mm2Â Â to 800 mm2,muli-core cable from 1.5 mm2Â Â to 400 mm2
Â
6).operating characteristics:
Rated power-frequency voltage u0/u:0.6/1 KV
Max permissible continuous operating temperature of conductor 70
Max short-circuit temperature of the conductor shall not exceed (Max 5 seconds duration): cross-section of conductor 300 mm2
 Â
The bending radius of single core cable should not be less than 20 times of the cable diameter ,the bending radius of multi-core cable should not be less than 15 times of the cable diameter
Â
Optical filter is a kind of optical element that selectively selects the transmission, reflection, cut-off and attenuation of spectral wavelength. According to its function, it can be divided into band pass filter, long wave pass filter, short wave pass filter, two Color filters, neutral density filters (ND Filter), notch filters, cold mirrors, hot mirrors, color filters, etc. Divided into interference filters and color absorption filters. These filters are widely used in industries and product fields such as spectral analysis, biomedicine, machine vision, fluorescence microscopy, and industrial automation. The band-pass filter selectively allows certain spectral wavelengths to pass through and prevents certain spectral wavelengths from passing through in its spectral range; the neutral density filter (ND Filter) reduces the transmittance of the specified spectral wavelength range, thereby Reduce luminous flux, which is conducive to the protection of sensors/electronic components. It has a wide range of applications in the field of laser optics/optoelectronics; cold/hot mirrors can specifically reflect and transmit light with longer wavelengths in the spectral range, and are widely used Applied in the lighting system, it is helpful to remove the heat generated in the lighting system.
Beam Splitter Filter,Nawrrow Bandpass Filter,Longpass Filter,Shortpass Filter
Bohr Optics Co.,Ltd , https://www.bohr-optics.com